Sunday 3 March 2019

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 466

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 466



- DME fault entry P0685 with FreezeFrame actual value >A010-DME SUPPLY VOLTAGE< = 0 V



- NO DME fault entry P0686 because these diagnostic conditions (> 8.0 V at A34) were not met.



- Start voltage > 5 V ... < 6 V + DME main relay is working:



- Starter turns



- Engine does not start



- DME fault entry P0685 with FreezeFrame actual value [A010-DME SUPPLY VOLTAGE] > 5 V ... < 6 V



- NO DME fault entry P0686 because these diagnostic conditions (> 8.0 V at A34) were not met.



- Start voltage > 6 V ... < 8 V + DME main relay does NOT function:



- Starter turns



- Engine does not start



- DME fault entry P0685 with FreezeFrame actual value >A010-DME SUPPLY VOLTAGE< = 0 V



- NO DME fault entry P0686 because these diagnostic conditions (> 8.0 V at A34) were not met.



- Start voltage > 6 V + DME main relay is working:



- Starter turns



- Engine starts



- NO DME fault entries



- Start voltage > 8 V + DME main relay does NOT function:



- Starter turns



- Engine does not start



- DME fault entry P0685 with FreezeFrame actual value >A010-DME SUPPLY VOLTAGE< = 0 V



- DME fault entry P0686 with FreezeFrame actual value >A010-DME SUPPLY VOLTAGE< = 0 V



II. Behavior and displays in the E2 with WS5890 or higher:



- Start voltage < 5 V:



- Starter might turn



- Engine does not start



- NO DME fault entries because the DME (DFI) control unit is not viable.



- Start voltage > 5 V ... < 8 V + DME main relay does NOT function:



- Starter turns



- Engine does not start



- DME fault entry P0685 with FreezeFrame actual value >A010-DME SUPPLY VOLTAGE< = 0 V



- NO DME fault entry P0686 because these diagnostic conditions (> 8.0 V at A34) were not met.



- Start voltage > 5 V ... < 8 V + DME main relay is working:



- Starter turns



- Engine starts



- NO DME fault entries



- Start voltage > 8 V + DME main relay does NOT function:



- Starter turns



- Engine does not start



- DME fault entry P0685 with FreezeFrame actual value >A010-DME SUPPLY VOLTAGE< = 0 V



- DME fault entry P0686 with FreezeFrame actual value > >A010-DME SUPPLY VOLTAGE< = 0 V



- Start voltage > 8 V + DME main relay is working:



- Starter turns



- Engine starts



- NO DME fault entries



P0686



P0686



Diagnosis information - Control unit DME (DFI)



Main relay off



Diagnostic conditions



- Vehicle voltage > 8.0 V



- Ignition off



- Control unit run-on completed (See [Information])



- then Ignition on



Possible fault causes



- Main relay Faulty (Contact stuck)



- Short circuit to B+ Lead between Main relay and Control unit DME (DFI) (Power supply Control unit DME (DFI))



- Short circuit to ground Lead between Control unit DME (DFI) and Main relay (Activation Main relay)