Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not saved: P1833



- The following fault is not saved: P183B



Possible fault causes



- Line between selector lever control unit and PDK control unit faulty



- Actuator solenoid for R/P interlock faulty



- PDK control unit faulty



Fault setting conditions



- Internal current measurement, actuator solenoid R/P: current consumption = 0 mA



Fault effects



- Transmission limp-home indication in instrument cluster control unit



With P0931



P0931



Diagnosis information - PDK



Actuator solenoid R/P interlock, short circuit to ground



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- The following fault is not stored: P1833



- The following fault is not stored: P183B



Possible fault causes



- Line between selector lever control unit and PDK control unit faulty



- Actuator solenoid for R/P interlock faulty



- PDK control unit faulty



Fault effects



- Transmission limp-home indication in instrument cluster control unit



Actuator Solenoid R/P Interlock, Open Circuit



P0931



Diagnosis information - PDK



Actuator solenoid R/P interlock, open circuit



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not saved: P1833



- The following fault is not saved: P183B



Possible fault causes



- Line between selector lever control unit and PDK control unit faulty



- Actuator solenoid for R/P interlock faulty



- PDK control unit faulty



Fault setting conditions



- Internal current measurement, actuator solenoid R/P: current consumption = 0 mA



Fault effects



- Actuator solenoid for R/P interlock switch-off



- Selector lever fixed in position P.