Wednesday 5 June 2019

2000 Porsche Boxster (986) F6-2.7L A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 73


3 Check output stage of DME control module.



1. Connect special tool 9637.



2. Remove oxygen sensor connector 1 ahead of TWC.



3. Connect voltmeter to pins II/9 and II/15.



4. Switch on the ignition.



Display: approx. 450 mV



If the display reads less then 400 mV or greater then 500 mV, replace DME control module.



4 Perform adaptation.



1. Switch on the ignition.



2. Wait one minute.



Do not press the accelerator.



3. Switch off the ignition for at least 10 seconds.



4. Read out the fault memory.



02 Sensor Circuit



P0130



02 Sensor Circuit



NOTE: The diagnosis for this fault is different for models with turbo engines and models with naturally-aspirated engines.



Diagnosis/troubleshooting - all turbo models



NOTE: The DTC (diagnostic trouble code) covers all electrical faults here.



Diagnostic conditions



- Engine temperature greater than 60 锟斤拷C



- 3 minutes idle speed, then 30 seconds increased idle speed



Possible cause of fault



- Short circuit to B+



- Short circuit to ground



- Open circuit



- Oxygen sensor faulty



- Control module faulty



Affected pins



DME control module connector II, pin 9 and oxygen sensor jack, bank 1, pin 5



DME control module connector II, pin 15 and oxygen sensor jack, bank 1, pin 1



DME control module connector II, pin 2 and pin 5



Diagnosis/troubleshooting



NOTE: Do not use contact spray on the oxygen sensor plug connections as this may cause irreparable damage to the wiring (contamination of the



oxygen sensor via the reference air channel).