Diagnostic and Repair Information ,Wiring Diagrams. DTC. TSB. Types: TSB, DTC, Wiring Diagrams, OEM Procedures. Trusted by more than 400,000 technicians. OEM accurate fix for faster repairs. Repair Procedures and Labor Times. Factory Auto Repair info. Request A Demo Today. Factory-Correct Diagrams. Factory Part Numbers. Maintenance Schedules. Repair Procedures. Labor Times. Types: TSB, DTC.car insurance, auto insurance, auto, car, vehicle, insurance, quote, quotes, online, insurance,auto, autos, car, cars, vehicle, vehicles, used car, pre-owned car, pre-owned vehicle, used auto, used vehicle, rental,auto racing news, car racing news
P0030
P0030
Diagnosis information - DME V6 DFI
Driver for oxygen sensor heater ahead of catalytic converter, bank 1
NOTE: Do not use contact spray on the oxygen sensor plug connections, as this may cause irreparable damage to the wiring (blocking the reference air channels).
NOTE: Do not confuse oxygen sensor ahead of catalytic converter and oxygen sensor behind catalytic converter as this will cause implausible fault entries.
Diagnostic conditions
- Battery positive voltage between 9 V and 16 V
- Time after engine starts > 10 seconds
Possible fault causes
- Short circuit to B+
- Short circuit to ground
- Open circuit in line
- Fuse FE 17 faulty (fuse carrier in plenum panel E-box)
- Loose contact in connector
- Oxygen sensor heater faulty
- Oxygen sensor faulty
Affected contacts on the DFI control unit connector
Connector [B]: - Contact 51
Affected contacts on the oxygen sensor connector behind catalytic converter, bank 1
- Contact 3