    U0402


    Diagnosis information - CAN Communication, Tiptronic control unit Diagnostic conditions

    The Tiptronic control unit initially tests internal function sequences after wake-up. If they are OK, all diagnosable outputs are then tested and any faults are stored.
    Tiptronic control unit wake-up through:

  • Event-induced CAN message
  • Ignition on

    Possible fault causes

  • No power supply for Tiptronic control unit
  • Tiptronic control unit is incorrectly coded
  • Short circuit or open circuit in the CAN drive
  • Tiptronic control unit faulty (in most cases the cause is not the Tiptronic control unit but incorrect coding.)

    Fault effects

  • Communication via the CAN drive is no longer possible
  • No other control units are able to communicate with the Tiptronic control unit

    Affected contacts on the Tiptronic control unit


    Connector [A]:
  • 1 ground supply - terminal 31
  • 2 ground supply - terminal 31
  • 3 power supply - terminal 30
  • 27 power supply - terminal 15
  • 28 power supply - terminal 15
  • 34 CAN drive low
  • 46 CAN drive high