- Oxygen sensor in front of catalytic converter Bank 2 Faulty



With P17AC



P2718



Diagnosis information - PDK



Electrical pressure adjuster 4, shunt



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not detected: P1832



- The following fault is not detected: P183A



- The following fault is not detected: P1842



Possible fault causes



- Shunt circuit in line between pressure regulator 4 and PDK control unit



- Pressure regulator 4 faulty



- PDK control unit faulty



Fault setting conditions



- Actual pressure regulator current < setpoint current (maximum deviation = 35 mA)



Fault effects



- Power supply switch-off, pressure regulator for system pressure and synchro selection



- Power supply switch-off, solenoid valves



- Pressure regulator for system pressure and synchro selection, switch-off



- Solenoid valves switch-off



- Last gear held



- Transmission limp-home indication in instrument cluster control unit



With P17A4



P2718



Diagnosis information - PDK



Electrical pressure adjuster 4, shunt



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not detected: P1832



- The following fault is not detected: P183A



- The following fault is not detected: P1842



Possible fault causes



- Shunt circuit in line between pressure regulator 4 and PDK control unit



- Pressure regulator 4 faulty



- PDK control unit faulty



Fault setting conditions



- Actual pressure regulator current > setpoint current (maximum deviation = 35 mA)



Fault effects



- Power supply switch-off, pressure regulator for system pressure and synchro selection



- Power supply switch-off, solenoid valves



- Pressure regulator for system pressure and synchro selection, switch-off



- Solenoid valves switch-off



- Last gear held



- Transmission limp-home indication in instrument cluster control unit



Pressure Regulator 4 (System Pressure), Open Circuit



P2718



Diagnosis information - PDK