1. Inspect the ground points for corrosion.
2. Clear fault memory.
Test Point 1
TEST POINT 1
Door(s) Secured And Terminal 15 On
Fault Code 01
Procedure
1. Disconnect plug connection X 11 (driver's side).
2. Check the line from X 11 pin A3 (pin side) to the alarm control unit plug I, pin 5, for continuity.
3. Check the lines from X 11 pin A3 and pin 26 (sleeve side) for continuity.
Note:
There is another plug connection in the door on the door lock module.
4. Disconnect plug connection X 12 (passenger's side).
5. Check the line from X 12 pin A3 (pin side) to the alarm control unit plug I, pin 28, for continuity.
6. Check the lines from X 12 pin A3 and pin 26 (sleeve side) for continuity.
Test Point 2
TEST POINT 2
Door Lock Barrel Closed, Activated Longer Than 60 Seconds
Fault Code 02
Note:
This fault can also be caused by incorrect operation (door lock actuated towards "Closed" direction for longer than 60 seconds).
Procedure
1. Pull off plug I at the alarm control unit.
2. Disconnect plug connection X 11 (driver's side).
3. Disconnect plug connection X 12 (passenger's side).
4. Check the lines from the alarm control unit plug I, pin 35, to the door lock modules for ground shorts.
Ohmmeter at the alarm control unit plug I, pin 35, and ground
Display: infinity
5. Check the driver's side door lock module switch contact.
Ohmmeter at plug X 11, pin A4 (sleeve side) and ground.
- Door lock not actuated.
Display: infinity
- Door lock actuated towards "Closed".
Display: < 5 ohms
6. Check the passenger's side door lock module switch contact.
Ohmmeter at plug X 12, pin A4 (sleeve side) and ground.