Tuesday 17 October 2017

P0155


P0155
P0155
Diagnosis information - DME V8 DFI
Heater circuit, oxygen sensor ahead of cat. converter, bank 2
NOTE: Do not use contact spray on the oxygen sensor plug connections, as this may cause irreparable damage to the wiring (blocking the reference
air channels).
NOTE: Do not interchange the oxygen sensor ahead of catalytic converter with the sensor behind the catalytic converter as this will result in
implausible fault entries.
Diagnostic conditions
- Time after engine starts > 10 seconds
- Oxygen sensor heater control active
- Lambda control active
- No driver fault of oxygen sensor stored
Possible fault causes
- Contact resistance between DME control unit and oxygen sensor heater ahead of catalytic converter, bank 2
- Contact resistance between fuse FE 17 (fuse carrier in plenum panel E-box) and oxygen sensor heater ahead of catalytic converter, bank 2
- High resistance shunt to signal line
- Oxygen sensor faulty
Affected contacts on the DME control unit connector
Connector [A]:
- Contact 46
Affected contacts on the oxygen sensor connector ahead of catalytic converter, bank 2:
- Contact 3