Tuesday 17 October 2017

P2A03

P2A03
P2A03
Diagnosis information - DME V8 DFI
Electric fault, oxygen sensor ahead of cat. converter, bank X
NOTE:
This fault indicates that the DME control unit has detected an implausible temperature range for the oxygen sensor.
Since lambda control is interrupted at this time, the DME control unit stores this fault as information. The more precise fault cause is stored as a
further P code.
NOTE: Do not use contact spray on the oxygen sensor's plug connections as this will result in irreparable damage to the lines (blockage of
reference air duct).
NOTE: Do not interchange the oxygen sensor ahead of catalytic converter with the sensor behind the catalytic converter as this will result in
implausible fault entries.
Diagnostic conditions
- Engine running > 30 seconds
- Exhaust temperature > 100 °C (212 °F)
- Oxygen sensor ahead of catalytic converter operational
- No overrun fuel shutoff
2010 Porsche Cayenne Turbo (9PA) V8-4.8L Turbo   Page 3
Possible fault causes
- Other electric oxygen sensor faults are stored in the fault memory