P183B
Diagnosis information - PDK
Power supply for P/R actuator solenoid, short circuit to ground
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1752
Possible fault causes
- Line between selector lever control unit and PDK control unit faulty
- Selector lever control unit faulty
- PDK control unit faulty
Fault setting conditions
- Actual measured voltage HS4 < 0.3 V
Fault effects
- Shiftlock power supply switch-off
- Shiftlock function switch-off
- No shift-lock function
- Selector lever is blocked in P and can be released only mechanically (emergency release)
- White transmission limp-home indication in instrument cluster
Power Supply For P/R Actuator Solenoid, Short-Circuit To B+
P183B
Diagnosis information - PDK
Power supply for P/R actuator solenoid, short-circuit to B+
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1752
Possible fault causes
- Line between selector lever control unit and PDK control unit faulty
- Selector lever control unit faulty
- PDK control unit faulty
Fault setting conditions
- Actual measured voltage HS4 > 4 V
Fault effects
- Shiftlock power supply switch-off
- Shiftlock function switch-off
- No shift-lock function
- Selector lever is blocked in P and can be released only mechanically (emergency release)
- White transmission limp-home indication in instrument cluster
Setpoint Definitions
P183B
Setpoint definitions
NOTE: The specified values and value ranges correspond to the OK state in each case.
2010 Porsche Cayman S (987) F6-3.4L Page 312
Line test setpoints
Short circuit to B+:
- Setpoint voltage - 0.5 V --> + 0.5 V
Short circuit to ground:
- Setpoint resistance > 0.9 MOhm
Open circuit:
- Setpoint resistance < 2 Ohm
Control unit setpoints
- Supply voltage terminal 30 9.1 V --> 16.4 V
- Voltage, terminal 15 9.5 V --> 16.0 V
Data Record For Shift Rod Compensation Is Invalid
Diagnosis information - PDK
Power supply for P/R actuator solenoid, short circuit to ground
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1752
Possible fault causes
- Line between selector lever control unit and PDK control unit faulty
- Selector lever control unit faulty
- PDK control unit faulty
Fault setting conditions
- Actual measured voltage HS4 < 0.3 V
Fault effects
- Shiftlock power supply switch-off
- Shiftlock function switch-off
- No shift-lock function
- Selector lever is blocked in P and can be released only mechanically (emergency release)
- White transmission limp-home indication in instrument cluster
Power Supply For P/R Actuator Solenoid, Short-Circuit To B+
P183B
Diagnosis information - PDK
Power supply for P/R actuator solenoid, short-circuit to B+
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1752
Possible fault causes
- Line between selector lever control unit and PDK control unit faulty
- Selector lever control unit faulty
- PDK control unit faulty
Fault setting conditions
- Actual measured voltage HS4 > 4 V
Fault effects
- Shiftlock power supply switch-off
- Shiftlock function switch-off
- No shift-lock function
- Selector lever is blocked in P and can be released only mechanically (emergency release)
- White transmission limp-home indication in instrument cluster
Setpoint Definitions
P183B
Setpoint definitions
NOTE: The specified values and value ranges correspond to the OK state in each case.
2010 Porsche Cayman S (987) F6-3.4L Page 312
Line test setpoints
Short circuit to B+:
- Setpoint voltage - 0.5 V --> + 0.5 V
Short circuit to ground:
- Setpoint resistance > 0.9 MOhm
Open circuit:
- Setpoint resistance < 2 Ohm
Control unit setpoints
- Supply voltage terminal 30 9.1 V --> 16.4 V
- Voltage, terminal 15 9.5 V --> 16.0 V
Data Record For Shift Rod Compensation Is Invalid