Friday, 10 August 2018

Porsche Cayman S P183A

P183A
Diagnosis information - PDK
Power supply for pressure regulators 4, 5 and 6 (system pressure and synchro selection) and solenoid valves, short circuit to B+
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1752
Possible fault causes
- Line between pressure regulator 4 and PDK control unit faulty
- Line between pressure regulator 5 and PDK control unit faulty
- Line between pressure regulator 6 and PDK control unit faulty
- Line between solenoid valves and PDK control unit faulty
- Pressure regulator 4, 5 or 6 faulty
- Solenoid valves faulty
- PDK control unit faulty
Fault setting conditions
- Actual measured voltage HS3 > 4 V
Fault effects
- Power supply switch-off, pressure regulators 4, 5 and 6
- Power supply switch-off, solenoid valves
- Pressure regulators 4, 5 and 6 switch-off
- Solenoid valves switch-off
- Gear held
- White transmission limp-home indication in instrument cluster
Power Supply For Pressure Regulators 4, 5 And 6 (System Pressure And Synchro Selection) And
Solenoid Valves, Open Circuit
P183A
Diagnosis information - PDK
Power supply for pressure regulators 4, 5 and 6 (system pressure and synchro selection) and solenoid valves, open circuit
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
2010 Porsche Cayman S (987) F6-3.4L   Page 310
- The following fault is not detected: P1752
Possible fault causes
- Line between pressure regulator 4 and PDK control unit faulty
- Line between pressure regulator 5 and PDK control unit faulty
- Line between pressure regulator 6 and PDK control unit faulty
- Line between solenoid valves and PDK control unit faulty
- Pressure regulator 4, 5 or 6 faulty
- Solenoid valves faulty
- PDK control unit faulty
Fault setting conditions
- Internal current measurement for pressure regulators 4, 5 and 6: current consumption = 0 mA
Fault effects
- Power supply switch-off, pressure regulators 4, 5 and 6
- Power supply switch-off, solenoid valves
- Pressure regulators 4, 5 and 6 switch-off
- Solenoid valves switch-off
- Gear held
- White transmission limp-home indication in instrument cluster
Power Supply For Pressure Regulators 4, 5 And 6 (System Pressure And Synchro Selection) And
Solenoid Valves, Short Circuit To G
P183A
Diagnosis information - PDK
Power supply for pressure regulators 4, 5 and 6 (system pressure and synchro selection) and solenoid valves, short circuit to ground
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1752
Possible fault causes
- Line between pressure regulator 4 and PDK control unit faulty
- Line between pressure regulator 5 and PDK control unit faulty
- Line between pressure regulator 6 and PDK control unit faulty
- Line between solenoid valves and PDK control unit faulty
- Pressure regulator 4, 5 or 6 faulty
- Solenoid valves faulty
- PDK control unit faulty
Fault setting conditions
- Actual measured voltage HS3 < 0.3 V
Fault effects
- Power supply switch-off, pressure regulators 4, 5 and 6
- Power supply switch-off, solenoid valves
- Pressure regulators 4, 5 and 6 switch-off
- Solenoid valves switch-off
- Gear held
- White transmission limp-home indication in instrument cluster
Setpoint Definitions
P183A
Setpoint definitions
NOTE: The specified values and value ranges correspond to the OK state in each case.
Line test setpoints
Short circuit to B+:
- Setpoint voltage - 0.5 V --> + 0.5 V
Short circuit to ground:
- Setpoint resistance > 0.9 MOhm
2010 Porsche Cayman S (987) F6-3.4L   Page 311
Open circuit:
- Setpoint resistance < 2 Ohm
Control unit setpoints
- Supply voltage terminal 30 9.1 V --> 16.4 V
- Voltage, terminal 15 9.5 V --> 16.0 V
Power Supply For P/R Actuator Solenoid, Short Circuit To Ground