1 Perform adaptation.
1. Switch on the ignition.
2. Wait one minute.
Do not press the accelerator.
3. Switch off the ignition for at least 10 seconds.
4. Read out the fault memory.
Throttle Jacking Unit, Control Range - Above Limit
P1505
404 Throttle Jacking Unit, Control Range - Above Limit
Diagnosis conditions
- Driving with changing pedal position
Possible fault cause
- Short circuit to ground
- Short circuit triggering wire
- Sluggish throttle
Affected terminals
Terminal I/7 and I/9
Diagnosis/Troubleshooting
Throttle Jacking Unit, Control Range - Below Limit
P1505
404 Throttle Jacking Unit, Control Range - Below Limit
Diagnosis conditions
- Driving with changing pedal position
Possible fault cause
- Open circuit
- Short circuit to B+
Affected terminals
Terminal I/7 and I/9
Diagnosis/Troubleshooting