P0013
P0013
Diagnosis information - DME V6 DFI
Exhaust camshaft adjustment driver
Diagnostic conditions
- Battery positive voltage 9 ... 16 V
- Time after engine starts > 10 seconds
Possible fault causes
- Open circuit in activation line
- Short circuit to ground in control line
- Short circuit to B+ in activation line
- Open circuit in voltage supply
- Fuse F12 faulty (fuse carrier in plenum panel E-box)
- K7 connection point disconnected
- Exhaust camshaft adjuster faulty
Affected contacts on the DFI control unit connector
Connector [A]: - Contact 21
Affected contacts on the exhaust camshaft adjuster connector
- Contact 1
- Contact 2
NOTE: The line for fuse F12 and contact 1 of the exhaust camshaft adjuster connector is routed via contact 4 of the KE 7 connection point.
PORSCHE Diagnostic and Repair Information ,Wiring Diagrams. DTC. TSB. Types: TSB, DTC, Wiring Diagrams, OEM Procedures. Trusted by more than 400,000 technicians. OEM accurate fix for faster repairs. Repair Procedures and Labor Times. Factory Auto Repair info. Request A Demo Today. Factory-Correct Diagrams. Factory Part Numbers. Maintenance Schedules. Repair Procedures. Labor Times. Types: TSB, DTC.