Porsche Diagnostic and Repair Information ,Wiring Diagrams. DTC. TSB. Types: TSB, DTC, Wiring Diagrams, OEM Procedures. Trusted by more than 400,000 technicians. OEM accurate fix for faster repairs. Repair Procedures and Labor Times. Factory Auto Repair info. Request A Demo Today. Factory-Correct Diagrams. Factory Part Numbers. Maintenance Schedules. Repair Procedures. Labor Times. Types: TSB, DTC.car insurance, auto insurance, auto, car, vehicle, insurance, quote, quotes, online, insurance,auto, autos, car, cars, vehicle, vehicles, used car, pre-owned car, pre-owned vehicle, used auto, used vehicle, rental,auto racing news, car racing news
  • P2197

    P2197


    Diagnosis information - DME V6 DFI

    Oxygen sensor upstream of catalytic converter, bank 2 - signal too rich/lean NOTE:

  • Diagnosis detects a deviation between the lambda value measured by the oxygen sensor upstream and the value measured by the oxygen sensor downstream.
  • The deviation is eliminated through adaptation, a fault is only set once the adaptation limits are exceeded.
  • The most common fault cause is a leakage between the two oxygen sensors, resulting in the sensor downstream measuring more residual oxygen in the exhaust than the sensor upstream.

    Diagnostic conditions

  • Engine running
  • Oxygen sensing in front of catalytic converter active
  • No faults detected for oxygen sensor or oxygen sensor heater up and downstream
  • No fault for secondary air injection, catalytic converter or tank vent entered
  • Exhaust temperature between 350 °C and 870 °C (662 °F and 1,598 °F)

    Possible fault causes

  • Leakage in exhaust system between the two oxygen sensors
  • Oxygen sensor upstream faulty (contaminated/aged)