Thursday, 27 June 2019

U0155

  • U0155

    U0155


    Diagnosis information - CAN Instrument cluster, communication Diagnostic conditions

    The instrument cluster initially tests internal function sequences after wake-up. If they are OK, all diagnosable outputs are then tested and any faults are stored.
    Instrument cluster wake-up through:

  • Event-induced CAN message
  • Wake-up signal via wake-up line
  • Ignition on

    Possible fault causes

  • No power supply for instrument cluster
  • Instrument cluster incorrectly coded
  • Short circuit or open circuit in the CAN display
  • Instrument cluster faulty (in most cases the cause is not the instrument cluster but incorrect coding.)

    Fault effects

  • Communication via the CAN display is no longer possible.
  • No other control units are able to communicate with the instrument cluster.

    Affected contacts on the instrument cluster


    Connector [A]:
  • 8 power supply - terminal 30
  • 9 ground supply - terminal 31
  • 23 power supply - terminal 30
  • 24 ground supply - terminal 31

    Connector [B]:
  • 19 CAN display high
  • 20 CAN display low