U0155
Diagnosis information - CAN Instrument cluster, communication Diagnostic conditions
The instrument cluster initially tests internal function sequences after wake-up. If they are OK, all diagnosable outputs are then tested and any faults are stored.
Instrument cluster wake-up through:
Event-induced CAN message
Wake-up signal via wake-up line
Ignition on
Possible fault causes
No power supply for instrument cluster
Instrument cluster incorrectly coded
Short circuit or open circuit in the CAN display
Instrument cluster faulty (in most cases the cause is not the instrument cluster but incorrect coding.)
Fault effects
Communication via the CAN display is no longer possible.
No other control units are able to communicate with the instrument cluster.
Affected contacts on the instrument cluster
Connector [A]:
8 power supply - terminal 30
9 ground supply - terminal 31
23 power supply - terminal 30
24 ground supply - terminal 31
Connector [B]:
19 CAN display high
20 CAN display low