2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 599

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 599



- PDK control unit faulty



Fault setting conditions



- Internal bus error



Fault effects



- All pressure regulators, solenoid valves and shift-lock switch off



- Start enable only in position P



- No emergency program diagnosis



- Emergency hold function



- Transmission limp-home indication in instrument cluster control unit



With P1804



P1715



Diagnosis information - PDK



SPI error



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



Possible fault causes



- PDK control unit faulty



Fault setting conditions



- Internal bus error



Fault effects



- All pressure regulators, solenoid valves and shift-lock switch off



- Start enable only in position P



- Emergency hold function



- Transmission limp-home indication in instrument cluster control unit



Transmission Ratio Monitoring



P1715



Diagnosis information - PDK



Transmission ratio monitoring



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



Possible fault causes



- Speed sensors faulty



- Lines faulty



Fault setting conditions



- Rotational speed comparison of input shaft and output shaft supplies fault



Fault effects



- Limp-home message in instrument cluster



Diagnosis Information - PDK (Dual-Clutch Transmission)



P1715



Diagnosis information - PDK



SPI error



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are