2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 309
- Transmission faulty
Fault setting conditions
- Target gear 6th gear, actual gear is disengaged before pressure adjusters 5/6 are activated
- 4th gear is engaged instead of 6th gear
- No shift rod moves
NOTE: The individual detection times are temperature-dependent (cold 2 s, warm 1 s)
Fault effects
- Gear held
- Only gears 1, 2, 4 and 7 are possible
- Transmission limp-home indication in instrument cluster control unit
Synchro 7th Gear Not Engageable Or Gear Skip
P176C
Diagnosis information - PDK
Synchro 7th gear not engageable or gear skip
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following faults are not detected: P1731, P1732, P1733 or P1734
- The following faults are not detected: P1706 or P1707
- Alternative measure HSS3_OFF not active
Possible fault causes
- Hydraulics faulty (hydraulic control unit)
- Transmission faulty
Fault setting conditions
- Target gear 7th gear, actual gear is disengaged before pressure adjusters 5/6 are activated
- 5th gear is engaged instead of 7th gear
- No shift rod moves
NOTE: The individual detection times are temperature-dependent (cold 2 s, warm 1 s)
Fault effects
- Gear held
- Only gears R, 3, 5 and 6 are possible
- Transmission limp-home indication in instrument cluster control unit
Diagnosis Information - PDK (Dual-Clutch Transmission)
P176C
Diagnosis information - PDK
Synchro 1st gear not engageable or gear skip
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following faults are not detected: P1731, P1732, P1733 or P1734
- The following faults are not detected: P1706 or P1707
- Alternative measure HSS3_OFF not active
Possible fault causes
- Hydraulics faulty (hydraulic control unit)
- Transmission faulty
Fault setting conditions
- Target gear 1st gear, actual gear is disengaged before pressure adjusters 5/6 are activated
- 3. gear is engaged instead of 1st gear