2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 43

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 43



- Pressure regulator 6 faulty



- PDK control unit faulty



Fault setting conditions



- Actual pressure regulator current > setpoint current (maximum deviation = 35 mA)



Fault effects



- Power supply switch-off, pressure regulator for system pressure and synchro selection



- Power supply switch-off, solenoid valves



- Pressure regulator for system pressure and synchro selection, switch-off



- Solenoid valves switch-off



- Last gear held



- Transmission limp-home indication in instrument cluster control unit



Pressure Regulator 6 (Synchro Selection Gear: 4, 2, 1, 7), Open Circuit



P17A6



Diagnosis information - PDK



Pressure regulator 6 (synchro selection gear: 4, 2, 1, 7), open circuit



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not detected: P1832



- The following fault is not detected: P183A



- Pressure regulator 6 active



Possible fault causes



- Line between pressure regulator 6 and PDK control unit faulty



- Pressure regulator 6 faulty



- PDK control unit faulty



Fault setting conditions



- Internal current measurement, pressure regulator: current consumption = 0 mA



- Line resistance between pressure regulator 6 and PDK control unit > 1 MOhm



Fault effects



- Pressure regulator 6 switch-off



- Engaged gear is held until vehicle stops.



- Moving off possible only in following gear: 3rd gear



- Transmission limp-home indication in instrument cluster control unit



Diagnosis Information - PDK (Dual-Clutch Transmission)



P17A6



Diagnosis information - PDK



Electrical pressure adjuster 6, shunt



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not detected: P1832



- The following fault is not detected: P183A



- The following fault is not detected: P1842



Possible fault causes



- Shunt circuit in line between pressure regulator 6 and PDK control unit



- Pressure regulator 6 faulty



- PDK control unit faulty



Fault setting conditions