Fault code 10
1. Check battery.
2. Check the alarm control module power supply.
- Voltmeter at alarm control module plug II pin 1 (negative) and pin 7 (positive).
Display: Battery voltage.
NOTE: The positive lead (terminal 30) is fused in the distribution board with an 80 A fuse.
Test Point 11
Test point 11
Power failure during alarm output
Fault code 11
Troubleshooting in accordance with test point 10.
Test Point 12
Test point 12
Wrong door lock module
Fault code 12
NOTE: This fault concerns only USA vehicles. USA vehicles do not have the "Door secured" function.
1. Check the driver's side / passenger's side door lock module and, if necessary, replace it with a door lock module for USA vehicles.
Test Point 13
Test point 13
Left door secured but not locked
Fault code 13
1. Pull off plug I on the alarm control module.
2. Disconnect plug connection X 11 (driver's side).
3. Check the lead from the alarm control module plug I pin 30 to the door lock module for short to ground.
- Ohmmeter on alarm control module plug I pin 30 and ground.
Display: Infinity Ohms
4. Check driver's side door lock module switch contact.
- Ohmmeter at plug connection X 11 pin A5 (sleeve side) and ground.
Door locked
Display: Infinity Ohms
Door not locked
Display: < 5 Ohms
Test Point 14
Test point 14
Right door secured but not locked
Fault code 14
1. Pull off plug I on the alarm control module.
2. Disconnect the plug connection X 12 (passenger's side).
3. Check the lead from the alarm control module plug I pin 32 to the door lock module for short to ground.
- Ohmmeter at alarm control module plug I pin 32 and ground
Display: Infinity Ohms
4. Check passenger's side door lock module switch contact.
- Ohmmeter at plug connection X 12 pin A5 (sleeve side) and ground.
Door locked.
Display: Infinity Ohms