Display: < 5 ohms
Note:
There is another plug connection in the door on the door lock.
5. Switch ignition on
- Voltmeter at alarm system control module plug I, pin 28 and ground
Display: 0 Volts
6. Switch ignition off
- Ohmmeter at alarm system control module plug I, pin 28 and ground
Display: infinity
- Ohmmeter at alarm system control module plug I, pin 28 and the plug connection X 11, pin A 1 (pin side)
Display: < 5 ohms
Test Point 2
TEST POINT 2
Door Lock Barrel Closed, Activated Longer Than 60 Seconds
Fault Code 02
This fault can also be caused by incorrect operation (door lock actuated toward closed" direction for longer than 60 seconds).
Procedure
1. Pull plug I off the alarm system control module.
2. Disconnect plug connection X 11 (driver's side).
3. Disconnect plug connection X 12 (passenger's side).
4. Check the wires from the alarm system control module plug I, pin 35 to the door locks for short to ground.
Ohmmeter at alarm system control module plug I, pin 35 and ground
Display: infinity
5. Check driver's side door lock switch contact.
Ohmmeter at plug connection X 11, pin A2 (sleeve side) and ground.
- Door lock not actuated.
Display: infinity
- Door lock actuated towards "Closed".
Display: < 5 ohms
6. Check passenger's side door lock switch contact.
Ohmmeter at plug connection X 12, pin A2 (sleeve side) and ground.
- Door lock not actuated.
Display: infinity
- Door lock actuated towards "Closed".