Work Instruction 1 - 6
Test Point 1
NOTE: After a fault occurs at the alarm system and is remedied, the fault memory must be cleared.
Test point 1
Door(s) secured and terminal 15 on
Fault code 01
1. Disconnect plug connection X 11 (driver's side).
2. Check the lead from X 11 pin A3 (pin side) to the alarm control module plug I, pin 5, for continuity.
3. Check the leads from X 11 pin A3 and pin 26 (sleeve side) for continuity.
NOTE: There is another plug connection in the door on the door lock module.
4. Disconnect the plug connection X 12 (passenger's side).
5. Check the lead from X 12 pin A3 (pin side) to the alarm control module plug I, pin 28, for continuity.
6. Check the leads from X 12 pin A3 and pin 26 (sleeve side) for continuity.
Test Point 2
Fault code 02
NOTE: This fault can also be caused by incorrect operation (door lock actuated toward "closed" direction for longer than 60 seconds).
1. Pull off plug I on the alarm control module.
2. Disconnect plug connection X 11 (driver's side).
3. Disconnect the plug connection X 12 (passenger's side).
4. Check the leads from the alarm control module plug I pin 35 to the door lock modules for short to ground.
- Ohmmeter at alarm control module plug I pin 35 and ground
Display: Infinity Ohms
5. Check driver's side door lock module switch contact.