Monday, 11 April 2022

2000 Porsche Boxster (986) F6-2.7L A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 110


Test Point 6



Test point 6



Door lock barrel open/closed



Short to ground



Fault code 06



1. Pull off plug I on the alarm control module.



2. Disconnect plug connection X 11 (driver's side).



3. Disconnect the plug connection X 12 (passenger's side).



4. Check the leads from the alarm control module plug I pin 35 to the door lock modules for short to ground.



- Ohmmeter at alarm control module plug I pin 35 and ground



Display: Infinity Ohms



5. Check driver's side door lock module switch contact.



- Ohmmeter at plug connection X 11 pin A4 (sleeve side) and ground.



Door lock not actuated.



Display: Infinity Ohms



Door lock actuated towards "Closed".



Display: < 5 Ohms



6. Check passenger's side door lock module switch contact.



- Ohmmeter at plug connection X 12 pin A4 (sleeve side) and ground.



Door lock not actuated.



Display: Infinity Ohms



Door lock actuated towards "Closed".



Display: < 5 Ohms



7. Check the leads from the alarm control module plug I pin 15 to the door lock modules for short to ground.



- Ohmmeter on alarm control module plug I pin 15 and ground.



Display: Infinity Ohms



8. Check driver's side door lock module switch contact.



- Ohmmeter at plug connection X 11 pin A6 (sleeve side) and ground.



Door lock not actuated.



Display: Infinity Ohms



Door lock actuated towards "Open".



Display: < 5 Ohms



9. Check passenger's side door lock module switch contact.



- Ohmmeter at plug connection X 12 pin A6 (sleeve side) and ground.



Door lock not actuated.



Display: Infinity Ohms



Door lock actuated towards "Open".



Display: < 5 Ohms



Test Point 7



Test point 7



Central locking button closed



Short to B+



Fault code 07



1. Pull off plug I on the alarm control module.



2. Check the central locking button.



- Voltmeter at plug I pin 29 and ground.



Central locking button not actuated.



Display: 0 V



Central locking button actuated towards "Closed".



Display: Battery voltage.



3. Disconnect the plug connection at the central locking button.