Test Point 6
Test point 6
Door lock barrel open/closed
Short to ground
Fault code 06
1. Pull off plug I on the alarm control module.
2. Disconnect plug connection X 11 (driver's side).
3. Disconnect the plug connection X 12 (passenger's side).
4. Check the leads from the alarm control module plug I pin 35 to the door lock modules for short to ground.
- Ohmmeter at alarm control module plug I pin 35 and ground
Display: Infinity Ohms
5. Check driver's side door lock module switch contact.
- Ohmmeter at plug connection X 11 pin A4 (sleeve side) and ground.
Door lock not actuated.
Display: Infinity Ohms
Door lock actuated towards "Closed".
Display: < 5 Ohms
6. Check passenger's side door lock module switch contact.
- Ohmmeter at plug connection X 12 pin A4 (sleeve side) and ground.
Door lock not actuated.
Display: Infinity Ohms
Door lock actuated towards "Closed".
Display: < 5 Ohms
7. Check the leads from the alarm control module plug I pin 15 to the door lock modules for short to ground.
- Ohmmeter on alarm control module plug I pin 15 and ground.
Display: Infinity Ohms
8. Check driver's side door lock module switch contact.
- Ohmmeter at plug connection X 11 pin A6 (sleeve side) and ground.
Door lock not actuated.
Display: Infinity Ohms
Door lock actuated towards "Open".
Display: < 5 Ohms
9. Check passenger's side door lock module switch contact.
- Ohmmeter at plug connection X 12 pin A6 (sleeve side) and ground.
Door lock not actuated.
Display: Infinity Ohms
Door lock actuated towards "Open".
Display: < 5 Ohms
Test Point 7
Test point 7
Central locking button closed
Short to B+
Fault code 07
1. Pull off plug I on the alarm control module.
2. Check the central locking button.
- Voltmeter at plug I pin 29 and ground.
Central locking button not actuated.
Display: 0 V
Central locking button actuated towards "Closed".
Display: Battery voltage.
3. Disconnect the plug connection at the central locking button.