Test Point 25
TEST POINT 25
No Terminal 86 S Recognized
Fault Code 25
Procedure
1. Check the fuse F 5/1.
2. Pull off plug I at the alarm control unit.
3. Voltmeter at plug I alarm control unit pin 16 and ground. Insert the ignition key into the ignition lock.
Display: Battery voltage
4. Pull off the plug on the ignition lock.
5. Ohmmeter at ignition lock connector pin 86 S and plug I, alarm control unit pin 16.
Display: < 5 ohms
6. If no fault is detected, replace the electrical contact part of the ignition lock.
Test Point 26
TEST POINT 26
Variant Fault (New Coding Required)
Fault Code 26
Procedure
Recode equipment variant