Thursday, 5 May 2022

2000 Porsche Boxster (986) F6-2.7L A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 231


3. Disconnect plug connection X 12 (passenger's side).



4. Switch on the ignition.



5. Voltmeter at plug II, pin 9 and ground.



Display: 0 Volts



6. Voltmeter at plug II, pin 3 and ground.



Display: 0 Volts



7. Switch off the ignition.



8. Ohmmeter at plug connection X 11, pin 19 and pin 20 (sleeve side).



Display: 5 - 7 ohms @ 20 锟斤拷C



9. Ohmmeter at plug connection X 12, pin 19 and pin 20 (sleeve side).



Display: 5 - 7 ohms @ 20 锟斤拷C



Test Point 1



TEST POINT 1



Outside Sensor On Right Does Not Function



Fault Code 1



This fault is stored in the following cases:



1. Open circuit in the supply lead to the outside sensor on right.



2. Short to B+ in the supply lead to the outside sensor on right.



3. Short to ground in the supply lead to the outside sensor on right.



Elimination:



- Delete fault memory, disengage reverse gear and switch off ignition. Then switch on ignition, engage reverse gear again and read out fault



memory.



- If the fault reappears, check plug on sensor for open circuit.



- If there is no open circuit, check for continuity with an ohmmeter from sensor connector pin 1 to pin 4 and pin 1 to pin 2. Continuity should



not be measured.



- If no short circuit can be detected, replace sensor.



Test Point 2



TEST POINT 2



Inside Sensor On Right Does Not Function



Fault Code 2



This fault is stored in the following cases:



1. Open circuit in the supply lead to the inside sensor on right.



2. Short to B+ in the supply lead to the inside sensor on right.



3. Short to ground in the supply lead to the inside sensor on right.



Elimination:



- Delete fault memory, disengage reverse gear and switch off ignition. Then switch on ignition, engage reverse gear again and read out fault



memory.



- If the fault reappears, check plug on sensor for open circuit.



- If there is no open circuit, check for continuity with an ohmmeter from sensor connector pin 1 to pin 4 and pin 1 to pin 2. Continuity should



not be measured.



- If no short circuit can be detected, replace sensor.