2000 Porsche Boxster (986) F6-2.7L A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 22


Part 1



Part 2



Fault Code 20



Alarm system I32; 148



Fault code 20



Status lead, signal converter, short circuit to ground



Diagnostic conditions



- Pin 86S switched on



Possible cause of fault



- Short circuit to ground in the wire between the alarm system control module and the signal converter



Affected terminals



Plug A, pins 3 and 4



Diagnosis/troubleshooting