Passenger compartment monitoring sensor, short circuit to ground
Diagnostic conditions
- Alarm system activated
Possible cause of fault
- Short circuit to ground/open circuit in the wire between the alarm system control module and the passenger compartment monitoring sensor
Affected terminals
Plug A, pin 24
Diagnosis/troubleshooting
Fault Code 23
Alarm system I32; 148
Fault code 23
W lead (DME immobiliser), short circuit to B+
Diagnostic conditions
- Ignition on
Possible cause of fault
- Short circuit to voltage in the communication lead between the alarm system control module and the DME control module
Affected terminals
Plug A, pin 23
Diagnosis/troubleshooting